Difference between revisions of "High-Performance Detection of Internally Reflected Cherenkov Light (DIRC)"
(Created page with "'''High-Performance DIRC''' [https://userweb.jlab.org/~sallison/analysis/newfits.php link study1]") |
(→Ongoing studies) |
||
(14 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | + | == Summary of current status == | |
− | [ | + | The EIC DIRC design is inspired by the design of the PANDA Barrel DIRC detector and many synergies exist in the R&D processes of both projects. The primary goal of developing a high-performance DIRC is to have a compact device that can satisfy the PID requirements of the EIC. |
+ | |||
+ | [[File:DIRC2.png|frameless|center|upright=0.85]] | ||
+ | |||
+ | The baseline design, implemented in a Geant4 simulation, is shown above. The radiators are synthetic fused silica bars, each 4200 mm long, with a cross-section of 17 mm × 35.4 mm divided into 16 modules, called bar boxes. In each box eleven bars are placed side-by-side and separated by a small air gap. The 16 bar boxes are arranged in a barrel with a radius of 1m around the beam line. Mirrors are attached to one end of each bar. On the readout end, where photons exit the bar, a special 3-layer lens, that will be described further, is attached to each bar. The other side of the 3-layer lens is coupled directly to a prism that serves as an expansion volume. A zoom into the readout end of the bar box, showing details of the lens and prism section is shown on a right side of Fig. 4. The prism is made of fused silica, has a 38 degrees opening angle, and has dimensions of 284.3 mm × 390 mm × 300 mm. The detector plane of each prism is covered by 27,690 2 mm × 2 mm pixels giving a total of about 443,040 channels to record the location and arrival time of the Cherenkov photons. | ||
+ | |||
+ | The focus on the 3-layer lens is shown below: | ||
+ | |||
+ | [[File:DIRC1.png|frameless|center|upright=0.85]] | ||
+ | |||
+ | Example of performance for selected polar angle of 7GeV/c proton is shown here: | ||
+ | |||
+ | [[File:MCperformance.png|frameless|center|upright=0.85]] | ||
+ | |||
+ | The resolution of reconstructed Cherenkov angle depends on the pixel size of sensor. Geant4 study of that aspect is summarized on the plot: | ||
+ | |||
+ | [[File:PXsize.png|frameless|center|upright=0.85]] | ||
+ | |||
+ | == Ongoing studies == | ||
+ | |||
+ | *[[CERN2015 Data Analysis]] | ||
+ | |||
+ | *[[Radiation Hardness at CUA ]] | ||
+ | |||
+ | *[[Mapping Focal Plane]] |
Latest revision as of 16:52, 13 June 2017
Summary of current status
The EIC DIRC design is inspired by the design of the PANDA Barrel DIRC detector and many synergies exist in the R&D processes of both projects. The primary goal of developing a high-performance DIRC is to have a compact device that can satisfy the PID requirements of the EIC.
The baseline design, implemented in a Geant4 simulation, is shown above. The radiators are synthetic fused silica bars, each 4200 mm long, with a cross-section of 17 mm × 35.4 mm divided into 16 modules, called bar boxes. In each box eleven bars are placed side-by-side and separated by a small air gap. The 16 bar boxes are arranged in a barrel with a radius of 1m around the beam line. Mirrors are attached to one end of each bar. On the readout end, where photons exit the bar, a special 3-layer lens, that will be described further, is attached to each bar. The other side of the 3-layer lens is coupled directly to a prism that serves as an expansion volume. A zoom into the readout end of the bar box, showing details of the lens and prism section is shown on a right side of Fig. 4. The prism is made of fused silica, has a 38 degrees opening angle, and has dimensions of 284.3 mm × 390 mm × 300 mm. The detector plane of each prism is covered by 27,690 2 mm × 2 mm pixels giving a total of about 443,040 channels to record the location and arrival time of the Cherenkov photons.
The focus on the 3-layer lens is shown below:
Example of performance for selected polar angle of 7GeV/c proton is shown here:
The resolution of reconstructed Cherenkov angle depends on the pixel size of sensor. Geant4 study of that aspect is summarized on the plot: