User contributions
(newest | oldest) View (newer 20 | older 20) (20 | 50 | 100 | 250 | 500)
- 22:10, 8 February 2017 (diff | hist) . . (+119) . . N File:420nm transmission.png (Transmission of NLaK and fused silica samples at 420 nm wavelength for different radiation doses along with trend lines) (current)
- 22:09, 8 February 2017 (diff | hist) . . (+4) . . High-Performance Detection of Internally Reflected Cherenkov Light (DIRC)
- 22:09, 8 February 2017 (diff | hist) . . (+6) . . High-Performance Detection of Internally Reflected Cherenkov Light (DIRC)
- 22:07, 8 February 2017 (diff | hist) . . (+4) . . NLaK Sample Measurement (170208)
- 22:07, 8 February 2017 (diff | hist) . . (+101) . . NLaK Sample Measurement (170208)
- 22:01, 8 February 2017 (diff | hist) . . (-2) . . NLaK Sample Measurement (170208)
- 21:58, 8 February 2017 (diff | hist) . . (-3) . . NLaK Sample Measurement (170208)
- 21:57, 8 February 2017 (diff | hist) . . (+8) . . NLaK Sample Measurement (170208)
- 21:55, 8 February 2017 (diff | hist) . . (+12) . . NLaK Sample Measurement (170208)
- 21:50, 8 February 2017 (diff | hist) . . (-12) . . NLaK Sample Measurement (170208)
- 21:49, 8 February 2017 (diff | hist) . . (-5) . . NLaK Sample Measurement (170208)
- 21:48, 8 February 2017 (diff | hist) . . (+10) . . NLaK Sample Measurement (170208)
- 21:47, 8 February 2017 (diff | hist) . . (+97) . . NLaK Sample Measurement (170208)
- 21:43, 8 February 2017 (diff | hist) . . (+976) . . N NLaK Sample Measurement (170208) (Created page with "File:NLaK1 ''NLaK Sample in holder in monochromator.'' File:NLaK3 ''NLaK sample in X-Ray setup.'' We decided to do first set of measurements using only NLaK sample...")
- 21:22, 8 February 2017 (diff | hist) . . (0) . . X-Ray setup calibration (170131)
- 21:21, 8 February 2017 (diff | hist) . . (0) . . File:Dosim.jpg (Greg uploaded a new version of File:Dosim.jpg) (current)
- 21:21, 8 February 2017 (diff | hist) . . (+1,349) . . N X-Ray setup calibration (170131) (Created page with "Calibration of X-Ray setup was performed using [http://www.raysafe.com/en/Products/Equipment/RaySafe%20ThinX#Downloads link RaySafe ThinX Rad] dosimeter (data sheet in link)...")
- 21:06, 8 February 2017 (diff | hist) . . (+75) . . N Radiation Hardness at CUA (Created page with "*X-Ray setup calibration (170131) *NLaK Sample Measurement (170208)") (current)
- 21:05, 8 February 2017 (diff | hist) . . (+71) . . N CERN2015 Data Analysis (Created page with "[https://userweb.jlab.org/~sallison/analysis/newfits.php link SPR fits]") (current)
- 21:04, 8 February 2017 (diff | hist) . . (-74) . . High-Performance Detection of Internally Reflected Cherenkov Light (DIRC) (→Ongoing studies)
(newest | oldest) View (newer 20 | older 20) (20 | 50 | 100 | 250 | 500)