User contributions
(newest | oldest) View (newer 50 | older 50) (20 | 50 | 100 | 250 | 500)
- 21:10, 8 February 2017 (diff | hist) . . (+119) . . N File:420nm transmission.png (Transmission of NLaK and fused silica samples at 420 nm wavelength for different radiation doses along with trend lines) (current)
- 21:09, 8 February 2017 (diff | hist) . . (+4) . . High-Performance Detection of Internally Reflected Cherenkov Light (DIRC)
- 21:09, 8 February 2017 (diff | hist) . . (+6) . . High-Performance Detection of Internally Reflected Cherenkov Light (DIRC)
- 21:07, 8 February 2017 (diff | hist) . . (+4) . . NLaK Sample Measurement (170208)
- 21:07, 8 February 2017 (diff | hist) . . (+101) . . NLaK Sample Measurement (170208)
- 21:01, 8 February 2017 (diff | hist) . . (-2) . . NLaK Sample Measurement (170208)
- 20:58, 8 February 2017 (diff | hist) . . (-3) . . NLaK Sample Measurement (170208)
- 20:57, 8 February 2017 (diff | hist) . . (+8) . . NLaK Sample Measurement (170208)
- 20:55, 8 February 2017 (diff | hist) . . (+12) . . NLaK Sample Measurement (170208)
- 20:50, 8 February 2017 (diff | hist) . . (-12) . . NLaK Sample Measurement (170208)
- 20:49, 8 February 2017 (diff | hist) . . (-5) . . NLaK Sample Measurement (170208)
- 20:48, 8 February 2017 (diff | hist) . . (+10) . . NLaK Sample Measurement (170208)
- 20:47, 8 February 2017 (diff | hist) . . (+97) . . NLaK Sample Measurement (170208)
- 20:43, 8 February 2017 (diff | hist) . . (+976) . . N NLaK Sample Measurement (170208) (Created page with "File:NLaK1 ''NLaK Sample in holder in monochromator.'' File:NLaK3 ''NLaK sample in X-Ray setup.'' We decided to do first set of measurements using only NLaK sample...")
- 20:22, 8 February 2017 (diff | hist) . . (0) . . X-Ray setup calibration (170131)
- 20:21, 8 February 2017 (diff | hist) . . (0) . . File:Dosim.jpg (Greg uploaded a new version of File:Dosim.jpg) (current)
- 20:21, 8 February 2017 (diff | hist) . . (+1,349) . . N X-Ray setup calibration (170131) (Created page with "Calibration of X-Ray setup was performed using [http://www.raysafe.com/en/Products/Equipment/RaySafe%20ThinX#Downloads link RaySafe ThinX Rad] dosimeter (data sheet in link)...")
- 20:06, 8 February 2017 (diff | hist) . . (+75) . . N Radiation Hardness at CUA (Created page with "*X-Ray setup calibration (170131) *NLaK Sample Measurement (170208)") (current)
- 20:05, 8 February 2017 (diff | hist) . . (+71) . . N CERN2015 Data Analysis (Created page with "[https://userweb.jlab.org/~sallison/analysis/newfits.php link SPR fits]") (current)
- 20:04, 8 February 2017 (diff | hist) . . (-74) . . High-Performance Detection of Internally Reflected Cherenkov Light (DIRC) (→Ongoing studies)
- 20:04, 8 February 2017 (diff | hist) . . (-12) . . High-Performance Detection of Internally Reflected Cherenkov Light (DIRC) (→Radiation Hardness at CUA)
- 20:01, 8 February 2017 (diff | hist) . . (-2) . . High-Performance Detection of Internally Reflected Cherenkov Light (DIRC) (→Summary of current status)
- 20:01, 8 February 2017 (diff | hist) . . (+51) . . High-Performance Detection of Internally Reflected Cherenkov Light (DIRC) (→Radiation Hardness at CUA)
- 20:00, 8 February 2017 (diff | hist) . . (-39) . . High-Performance Detection of Internally Reflected Cherenkov Light (DIRC) (→X-Ray setup calibration (170131))
- 19:59, 8 February 2017 (diff | hist) . . (+34) . . High-Performance Detection of Internally Reflected Cherenkov Light (DIRC) (→Radiation Hardness at CUA)
- 19:59, 8 February 2017 (diff | hist) . . (+80) . . High-Performance Detection of Internally Reflected Cherenkov Light (DIRC) (→Radiation Hardness at CUA)
- 19:56, 8 February 2017 (diff | hist) . . (0) . . N File:Coeffs mA.png (current)
- 19:56, 8 February 2017 (diff | hist) . . (0) . . N File:XRay dose.png (current)
- 19:55, 8 February 2017 (diff | hist) . . (0) . . N File:CalData.png (current)
- 19:46, 8 February 2017 (diff | hist) . . (0) . . N File:Dosim.jpg
- 19:42, 8 February 2017 (diff | hist) . . (0) . . N File:NLaK3.jpg (current)
- 19:41, 8 February 2017 (diff | hist) . . (0) . . N File:NLaK1.jpg (current)
- 19:40, 8 February 2017 (diff | hist) . . (0) . . N File:BeamSamp.png (current)
- 19:40, 8 February 2017 (diff | hist) . . (0) . . N File:Beam.png (current)
- 19:39, 8 February 2017 (diff | hist) . . (+33) . . High-Performance Detection of Internally Reflected Cherenkov Light (DIRC) (→Ongoing studies)
- 21:48, 25 January 2017 (diff | hist) . . (0) . . File:PXsize.png (Greg uploaded a new version of File:PXsize.png) (current)
- 21:47, 25 January 2017 (diff | hist) . . (+79) . . High-Performance Detection of Internally Reflected Cherenkov Light (DIRC)
- 21:43, 25 January 2017 (diff | hist) . . (+249) . . High-Performance Detection of Internally Reflected Cherenkov Light (DIRC)
- 21:40, 25 January 2017 (diff | hist) . . (0) . . N File:DIRC2.png (current)
- 21:40, 25 January 2017 (diff | hist) . . (+1,439) . . High-Performance Detection of Internally Reflected Cherenkov Light (DIRC)
- 21:31, 25 January 2017 (diff | hist) . . (0) . . N File:PXsize.png
- 21:31, 25 January 2017 (diff | hist) . . (0) . . N File:MCperformance.png (current)
- 21:30, 25 January 2017 (diff | hist) . . (0) . . N File:DIRC1.png (current)
- 21:25, 25 January 2017 (diff | hist) . . (+18) . . High-Performance Detection of Internally Reflected Cherenkov Light (DIRC)
- 21:24, 25 January 2017 (diff | hist) . . (0) . . N File:EIC.png (current)
- 17:56, 25 January 2017 (diff | hist) . . (+98) . . N High-Performance Detection of Internally Reflected Cherenkov Light (DIRC) (Created page with "'''High-Performance DIRC''' [https://userweb.jlab.org/~sallison/analysis/newfits.php link study1]")
(newest | oldest) View (newer 50 | older 50) (20 | 50 | 100 | 250 | 500)