NLaK Sample Measurement (170208)

From EIC-eRD14
Revision as of 21:39, 8 February 2017 by Greg (Talk | contribs)

Jump to: navigation, search
NLaK Sample in holder in monochromator
NLaK Sample in holder in monochromator


 NLaK sample in X-Ray setup.
NLaK sample in X-Ray setup.


First set of measurements was done using only NLaK sample placing it in the centre of the X-Ray setup shelf, directly under the source. That allows to be sure about the dose rate.

Calibration of X-Ray setup was done using dosimeter with 15mm radius circular sensor, since dose depends on the area we normalized dose for NLaK piece (28x8 mm). Dose for 7.5 s using dosimeter on shelve 8 was measured to be 81.4 R, so for NLaK it should be ~25R.

We used monochromator to quantify influence of irradiation by measuring transmission. We also had Fused Silica plate used as reference to normalize NLaK measurements. Below one can see that the beam of monochromator nicely fits in samples.

 Beam of monochromator right after NLaK (left) and Fused Silica (right) samples.
Beam of monochromator right after NLaK (left) and Fused Silica (right) samples.


We don't see much of a scattering of the beam:

Beam shape at the end of monochromator after going through NLaK sample (left), only air (right)


Transmission as a function of wavelength for few selected cases. No Fresnel correction was applied (+4% to transmission)
Transmission as a function of irradiation dose for 420nm in NLaK. Fused Silica plate is used as reference and is not irradiated. No Fresnel correction was applied (+4% to transmission)